Test Reports Stuc-O-Flex Finishes

TestMethodResult
Elongation % (Finish)105 Percent
Water Vapor TransmissionASTM-E9613 Grains Per Hour / Sq. Ft.(Average)
Salt Spray ResistanceB-117300 Hours
No Deleterious Effects
Accelerated WeatheringG-23-812000 Hours
No Deleterious Effects
Absorption Freeze Thaw60 CyclesNo Cracking, Checking
Tensile Bond StrengthASTM C-297 97.9 Psi Substrate Failure
Water Penetration TestASTM-E-331No Water Penetration Occurred On Substrate
Water Resistance TestASTM D-2247No Cracking, Blistering, Peeling Or Compromise
Mildew / Fungus Resistance During Test810 BNo Mold Or Mildew Growth
Wind Driven RainFED SPEC TT-C-555BNo Delamination
No Water Intrusion
Wind Loading Requirments (Excludes Mechanical Attatchment) Contact Technical Department For Additional Information On Wind Loading Issues ASTM E-330 Presures In Excess Of 156 Psi
Fire Testing Tunnel TestASTM E-84 Flame Spread < 25
Smoke Developed < 450
Class "A" Fire Rate